Publications

2024

Leuthner M., Reisbeck M., Helou M., Hayden O.: Towards a Point-of-Care Test of CD4+ T Lymphocyte Concentrations for Immune Status Monitoring with Magnetic Flow Cytometry. Micromachines. 2024; 15(4):520. https://doi.org/10.3390/mi15040520

Leuthner M., Reisbeck M., Helou M., Hayden O.: Towards a Point-of-Care Test of CD4+ T Lymphocyte Concentrations for Immune Status Monitoring with Magnetic Flow Cytometry. Micromachines. 2024; 15(4):520. https://doi.org/10.3390/mi15040520

Leuthner M. and Hayden, O.: Grease the gears: how lubrication of syringe pumps impacts microfluidic flow precision. Lab Chip, 2024, 24, 56. DOI: 10.1039/D3LC00698K

Leuthner M. and Hayden, Ol.: Grease the gears: how lubrication of syringe pumps impacts microfluidic flow precision. Lab Chip, 2024, 24, 56. DOI: 10.1039/D3LC00698K

 

2023

Christian Klenk, Johanna Erber, David Fresacher, Stefan Röhrl, Manuel Lengl, Dominik Heim, Hedwig Irl, Martin Schlegel, Bernhard Haller, Tobias Lahmer, Klaus Diepold, Sebastian Rasch, Oliver Hayden: Platelet aggregates detected using quantitative phase imaging associate with COVID-19 severity. Commun Med 3, 161 (2023). https://doi.org/10.1038/s43856-023-00395-6

Röhrl, S.; Bernhard, L.; Lengl, M.; Klenk, C.; Heim, D.; Knopp, M.; Schumann, S.; Hayden, O. and Diepold, K. (2023). Explainable Feature Learning with Variational Autoencoders for Holographic Image Analysis. In Proceedings of the 16th International Joint Conference on Biomedical Engineering Systems and Technologies (BIOSTEC 2023) - BIOIMAGING; ISBN 978-989-758-631-6; ISSN 2184-4305, SciTePress, pages 69-77. DOI: 10.5220/0011632800003414

Stefan Röhrl, Hendrik Maier, Manuel Lengl, Christian Klenk, Dominik Heim, Martin Knopp, Simon Schumann, Oliver Hayden, Klaus Diepold: Explainable Artificial Intelligence for Cytological Image Analysis. In: Juarez, J.M., Marcos, M., Stiglic, G., Tucker, A. (eds) Artificial Intelligence in Medicine. AIME 2023. Lecture Notes in Computer Science(), vol 13897. Springer, Cham. doi.org/10.1007/978-3-031-34344-5_10

Klenk, C.; Fresacher, D.; Röhrl, S.; Heim, D.; Lengl, M.; Schumann, S.; Knopp, M.; Diepold, K.; Holdenrieder, S. and Hayden, O. (2023). Measurement of Platelet Aggregation in Ageing Samples and After in-Vitro Activation. In Proceedings of the 16th International Joint Conference on Biomedical Engineering Systems and Technologies (BIOSTEC 2023) - BIOIMAGING; ISBN 978-989-758-631-6; ISSN 2184-4305, SciTePress, pages 57-65. DOI: 10.5220/0011634200003414

Gilbert, D.F., Friedrich, O., Wiest, J.: Assaying Proliferation Characteristics of Cells Cultured Under Static Versus Periodic Conditions. In: Friedrich, O., Gilbert, D.F. (eds) Cell Viability Assays. Methods in Molecular Biology, vol 2644. Humana, New York, NY, 2023. https://doi.org/10.1007/978-1-0716-3052-5_3

Eggert, S., Stetsenko, S., Wiest, J.: Cellasys #8: A Microphysiometric Assay for Real-Time Cell Analysis within 24 Hours. In: Friedrich, O., Gilbert, D.F. (eds) Cell Viability Assays. Methods in Molecular Biology, vol 2644. Humana, New York, NY, 2023. https://doi.org/10.1007/978-1-0716-3052-5_19

Sistermanns, J., Emken, E., Weirich, G., Hayden, O., & Utschick, W. (2023). Unsupervised high-throughput segmentation of cells and cell nuclei in quantitative phase images. arXiv preprint arXiv:2311.14639.

2022

Natan T. Shaked, Oliver Hayden: Label-free Biomedical Imaging and Sensing (LBIS) 2022

Hasanzadeh Kafshgari, M.; Hayden, O.: Advances in analytical microfluidic workflows for
differential cancer diagnosis, Nano Select, 2022, 4, 1, 1-47

Zurita, F., Grob, L., Erben, A., Del Duca, F., Clausen-Schaumann, H., Sudhop, S., Hayden, O., Wolfrum, B.: Fully 3D‐Printed Cuff Electrode for Small Nerve Interfacing, Advanced Materials Technologies, 2022, 8, 3, 2200989

B. Sailer, R. Barnkob, O. Hayden: Akustische Zellmanipulation in einer sphärischen Mikrofluidikkammer, 66, 5. MÜNCHNER POCT SYMPOSIUM, Neue Perspektiven für Querschnittstechnologien und erweiterte
Anwendungsgebiete

C. Dillitzer: Point-of-Care im Patienten – Entwicklung eines digitalisierten Spacers zur longitudinalen Verfolgung der Infektsituation bei zweizeitigem Totalendoprothesen(TEP)-Wechsel, 70, 5. MÜNCHNER POCT SYMPOSIUM, Neue Perspektiven für Querschnittstechnologien und erweiterte Anwendungsgebiete

C. Klenk, S. Röhrl, M. Cortina, D. E. Fresacher, K. Diepold, O. Hayden: Blutzellaggregate als neue
Biomarkerklasse für POC Hämatologie Automaten, 68, 5. MÜNCHNER POCT SYMPOSIUM, Neue Perspektiven
für Querschnittstechnologien und erweiterte Anwendungsgebiete

Eggert, S., Stetsenko, S., Szalata, R. and Wiest, J.: cellasys #8: A microphysiometric test to identify
serum-free cell culture media, LINZ 2022 – EUSAAT 2022 / ALTEX Proceedings2

Eggert, S., Wiest, J., Rosolowski, J. and Weber, T.: Practical workshop on replacing fetal bovine serum
(FBS) in life science research: From theory into practice, ALTEX, 2022, 712-713

Eggert, Sebastian; Stetsenko, Svitlana; Wiest, Joachim: Mikrophysiometrischer Test zur Evaluierung
serumfreier Zellkulturmedien, BIOspektrum, 2022, 28, 1, 60-61L

L. Daum, M. Leuthner, M. Reisbeck, O. Hayden: Magentoresistive Durchflusszytometrie für POCT, 84, 5. MÜNCHNER POCT SYMPOSIUM, Neue Perspektiven
für Querschnittstechnologien und erweiterte Anwendungsgebiete

Hein, Alice; Röhrl, Stefan; Grobel, Thea; Lengl, Manuel; Hafez, Nawal; Knopp, Martin; Klenk, Christian; Heim, Dominik; Hayden, Oliver; Diepold, Klaus: A Comparison of Uncertainty Quantification Methods for Active
Learning in Image Classification, 2022 International Joint Conference on Neural Networks (IJCNN), IEEE

M. Brischwein, O. Hayden: Sensor-Monitoring an in vitro 3D Tumormodellen, 73, 5. MÜNCHNER POCT YMPOSIUM, Neue Perspektiven für Querschnittstechnologien und erweiterte Anwendungsgebiete

O. Hayden: Platform technologies for cell function diagnostics, 58, 5. MÜNCHNER POCT SYMPOSIUM,
Neue Perspektiven für Querschnittstechnologien und erweiterte Anwendungsgebiete

Röhrl, S., Hein, A., Huang, L., Heim, D., Klenk, C., Lengl, M., Knopp, M., Hafez, N., Hayden, O., Diepold,
K..:
Outlier Detection using Self-Organizing Maps for Automated Blood Cell Analysis, 2nd Workshop on
Interpretable Machine Learning in Healthcare (IMLH 2022)

Thalhofer, Thomas; Keck, Mauro; Kibler, Sebastian; Hayden, Oliver: Capacitive Sensor and Alternating
Drive Mixing for Microfluidic Applications Using Micro Diaphragm Pumps, Sensors, 2022, 22, 3, 1273

Wiest, Joachim: Systems engineering of microphysiometry, Organs-on-a-Chip, 2022, 4, 100016

Baur, M. Reisbeck, M.,Hayden, O. Utschick, W.: "Joint Particle Detection and Analysis by a CNN and Adaptive Norm Minimization Approach," in IEEE Transactions on Biomedical Engineering, vol. 69, no. 8, pp. 2468-2479, Aug. 2022, doi: 10.1109/TBME.2022.3147701.

Klüpfel, J., Paßreiter, S., Weidlein, N., Knopp, M., Ungerer, M., Protzer, U., Knolle, P., Hayden, O., Elsner, M. and Seidel, M.: "Fully Automated Chemiluminescence Microarray Analysis Platform for Rapid and Multiplexed SARS-CoV-2 Serodiagnostics", Anal. Chem. 2022, 94, 6, 2855–2864, Publication Date:February 2, https://doi.org/10.1021/acs.analchem.1c04672

2021

Balbach, S., N. Jiang, R. Moreddu, X. Dong, W. Kurz, C. Wang, J. Dong, Y. Yin, H. Butt, M. Brischwein, O. Hayden, M. Jakobi, S. Tasoglu, A. W. Koch and A. K. Yetisen: "Smartphone-based colorimetric detection system for portable health tracking", Anal.Methods, 2021, 13, 4361–4369

Klenk, C., Wiest, J.: "cellasys #8: A microphysiometric assay to asses enhanced cell culture media", ALTEX Proceedings, 2021, 9, 1, 207

Schmidt, C., Wiest, J.: "Three-stage approach for evaluation of a chemically defined cell culture medium for the Caco-2 cell line: Short-term effects, differentiation potential and long-term cultivation", ALTEX Proceedings, 2021, 9, 1, 215

Szalata, R., Stetsenko, S., Wiest, J.: "Cytotoxicity of reference electrodes in microphysiometric systems revisited", ALTEX Proceedings, 2021, 9, 1, 335

Sailer, B. et al.: "Two-photon microscopy and acoustic trapping for the analysis of cell osmosis", MicroTAS 2021, 10.-14. October 2021, Hybrid Conference, Abstract No. 0615

2020

Barnkob, R. and M. Rossi: "General Defocusing Particle Tracking: Fundamentals and uncertainty assessment", Experiments in Fluids 61, 110 (2020).

Rossi, M. and R. Barnkob: "A fast and robust algorithm for general defocusing particle tracking", Meas Sci Technol 31, 014001 (2020).

Kim, M.,  R. Barnkob, and M. Meacham: "Microswimmers as living probes to measure the acoustic energy density in acoustofluidic", Acoustofluidics Virtual 2020 conference, 26-27 August 2020, pp. 23-24.

Sailer, B., R. Barnkob, and O. Hayden: "Acoustic particle trapping in a spherical microchamber", Acoustofluidics Virtual 2020 conference, 26-27 August 2020, pp. 131-132.

Nama, N. and R. Barnkob: "Analytical prediction of acoustic radiation forces in soft-walled microchannels driven by standing surface acoustic waves",  Acoustofluidics Virtual 2020 conference, 26-27 August 2020, pp. 131-132.

Barnkob, R. : "Experimental assessment and modeling of acoustophoretic particle trajectories", The 179th Meeting of the Acoustical Society of America, 7-11 December 2020, Acoustics Virtually Everywhere, pp. 2707.

Kim, M., R. Barnkob, and M. Meacham: "Quantifying the acoustic field in a microchannel using microswimmers as measurement probes", Proc. 24rd MicroTAS, 4-8 October 2020, Virtual Conference, pp. 162-163, CBMS, 2020.

Sailer, B., R. Barnkob, and O. Hayden: "Cell manipulation via acoustic forces in a spherical microchamber", Proc. 24rd MicroTAS, 4-8 October 2020, Virtual Conference, pp. 254-255, CBMS, 2020.

Schmidt, C. Markus, J. Kandarova, H., Wiest, J.: Tissue-on-a-Chip: Microphysiometry with human 3D-models on transwell inserts, Frontiers in Bioengineering and Biotechnology, 2020, 8:760, doi: 10.3389/fbioe.2020.00760

Klenk, C., Wiest, J.: cellasys #8: A microphysioimetric assay to asses enhanced cell culture media, 11th World Congress on Alternatives and Animal Use in the Life Science, Abstract overview, 2020, 33

Schmidt, C., Wiest, J.: Three-stage approach for evaluation of a chemically defined cell culture medium for the Caco-2 cell line: Short-term effects, differentiation potential and long-term cultivation, 11th World Congress on Alternatives and Animal Use in the Life Science, Abstract overview, 2020, 53

2019

Klenk, C., Heim, D., Ugele, M., Hayden, O.: "Impact of sample preparation on holographic imaging of leukocytes." Optical Engineering 59.10 (2019): 102403.

Yetisen, A.K.; Jiang, N.; Castaneda Gonzalez, C.M.; Erenoglu, Z.I.; Dong, J.; Dong, X.; Stößer, S.; Brischwein, M.; Butt, H.; Cordeiro, M.F.; Jakobi, M.; Hayden, O.; Koch, A.W.: Scleral Lens Sensor for Ocular Electrolyte Analysis. Advanced Materials, 1906762, doi: 10.1002/adma.201906762, 2019

Liu, J., Reisbeck, M. and Hayden, O.: “Investigation of mechanical and magnetophoretic focusing for magnetic flow cytometry,” Current Directions in Biomedical Engineering, vol. 5, pp. 353--, 2019

Hefele M, Wirths W, Brischwein M, Grothe H, Kreupl F, Wolf B: "Measuring fluorescence-lifetime and bio-impedance sensors for cell based assays using a network analyzer integrated circuit". Biosensors and Bioelectronics, 129 (2019) 292–297

2018

Maas M.B, Brischwein M., Los P., Perold W.J., Dicks L.: Evaluating non-linear impedance excitation as detection method for biosensors. IEEE Transactions on Nanotechnology. 2018, PP(99):1-1, DOI: 10.1109/TNANO.2018.2864572

Ugele M., Weniger M., Stanzel M., Bassler M., Krause S.W., Friedrich O., Hayden O.,5, Richter L.: Label-Free High-Throughput Leukemia Detection by Holographic Microscopy. Adv Sci (Weinh). eCollection, 2018 Oct 11;5(12):1800761. doi: 10.1002/advs.201800761.

Brischwein M., Wiest J.: Microphysiometry. In: Bioanalytical Reviews. Springer, Berlin, Heidelberg, 2018

Ugele M., Weniger M., Leidenberger M., Huang Y., Bassler M., Friedrich O., Kappes B., Hayden O., Richter L.: Label-free, high-throughput detection of P. falciparum infection in sphered erythrocytes with digital holographic microscopy. Lab Chip. 2018 Jun 12;18(12):1704-1712. doi: 10.1039/c8lc00350e.

Reisbeck M., Richter L., Helou M.J., Arlinghaus S., Anton B., van Dommelen I., Nitzsche M., Baßler M., Kappes B., Friedrich O., Hayden O.: Hybrid integration of scalable mechanical and magnetophoretic focusing for magnetic flow cytometry. Biosens Bioelectron. 2018 Jun 30;109:98-108. doi: 10.1016/j.bios.2018.02.046. Epub 2018 Mar 15.

Barnkob R., Nama N., Ren L., Huang T. J., Costanzo F., and Kähler C. J.: Acoustically Driven Fluid and Particle Motion in Confined and Leaky Systems, Phys Rev Applied, 2018, 9, 014027

2016

Reisbeck M., Helou M.J., Richter L., Kappes B., Friedrich O., Hayden O.: Magnetic fingerprints of rolling cells for quantitative flow cytometry in whole blood. Scientific reports. 2016;6:32838.

Hayden O.: One Binder to Bind Them All. Sensors. 2016;16(10):1665.

Wirth R., Ugele M., Wanner G.: Motility and Ultrastructure of Spirochaeta thermophila. Front Microbiol. eCollection, 2016 Oct 14;7:1609.

Wiest J, Namias A, Pfister C, Wolf P, Demmel F, Brischwein M.: Data Processing in Cellular Microphysiometry. IEEE Transactions on Biomedical Engineering. 2016, 63:2368-2375

2015

Docter D, Strieth S, Westmeier D, Hayden O, Gao M, Knauer SK, et al.: No king without a crown–impact of the nanomaterial-protein corona on nanobiomedicine. Nanomedicine. 2015;10(3):503-19.

Demmel F, Brischwein M, Wolf P, Huber F, Pfister C, Wolf B.: Nutrient depletion and metabolic profiles in breast carcinoma cell lines measured with a label-free platform. Physiological Measurement. 2015, 36:1367-1381.

Pfister C, Forstmeier C, Biedermann J, Schermuly J, Demmel F, Wolf P, Kaspers B, Brischwein M.: Estimation of dynamic metabolic activity in micro-tissue cultures from sensor recordings with an FEM model. Medical and Biological Engineering and Computing. 2015, 54:763-772

Pfister C, Bozsak C, Wolf P, Demmel F, Brischwein M.: Cell shape-dependent shear stress on adherent cells in a micro-physiologic system as revealed by FEM. Physiological Measurement. 2015, 36:955-966

Barnkob R., Kähler C. J., and Rossi M.: General defocusing particle tracking, Lab Chip, 2015, 15, 3556-3560

Nama N., Barnkob R., Mao Z., Kähler C. J., Costanzo F., and Huang T. J.: Numerical study of acoustophoretic motion of particles in a PDMS microchannel driven by surface acoustic waves, Lab Chip, 2015, 15, 2700-2809

2014

Hayden O.: Grand challenges for translational materials science. Frontiers in Materials. 2014;1:5.

Haigh PA, Ghassemlooy Z, Papakonstantinou I, Arca F, Tedde SF, Hayden O, et al.: A 1-Mb/s visible light communications link with low bandwidth organic components. IEEE Photonics Technology Letters. 2014;26(13):1295-8.

Mora M., Bellack A., Ugele M., Hopf J., Wirth R.: The temperature gradient-forming device, an accessory unit for normal light microscopes to study the biology of hyperthermophilic microorganisms. Appl Environ Microbiol. 2014 Aug;80(15):4764-70. doi: 10.1128/AEM.00984-14. Epub 2014 May 23.

2013

Popescu BV, Popescu DH, Lugli P, Locci S, Arca F, Tedde SF, et al.: Modeling and simulation of organic photodetectors for low light intensity applications. IEEE Transactions on Electron Devices. 2013;60(6):1975-81.

Leberl D, Ummethala R, Leonhardt A, Hensel B, Tedde SF, Schmidt O, et al.: Characterization of carbon nanotube field emitters in pulsed operation mode. Journal of Vacuum Science & Technology B, Nanotechnology and Microelectronics: Materials, Processing, Measurement, and Phenomena. 2013;31(1):012204.

Latif U, Can S, Hayden O, Grillberger P, Dickert FL.: Sauerbrey and anti-Sauerbrey behavioral studies in QCM sensors—Detection of bioanalytes. Sensors and Actuators B: Chemical. 2013;176:825-30.

Helou M., Reisbeck M., Tedde S.F., Richter L., Bär L., Bosch J.J., et al.: Time-of-flight magnetic flow cytometry in whole blood with integrated sample preparation. Lab on a Chip. 2013;13(6):1035-8.

Ghassemlooy Z, Haigh PA, Arca F, Tedde SF, Hayden O, Papakonstantinou I, et al.: Visible light communications: 3.75 Mbits/s data rate with a 160 kHz bandwidth organic photodetector and artificial neural network equalization. Photonics Research. 2013;1(2):65-8.

Charwat V, Rothbauer M, Tedde SF, Hayden O, Bosch JJ, Muellner P, et al.: Monitoring dynamic interactions of tumor cells with tissue and immune cells in a lab-on-a-chip. Analytical chemistry. 2013;85(23):11471-8.

Charwat V, Purtscher M, Tedde SF, Hayden O, Ertl P.: Standardization of microfluidic cell cultures using integrated organic photodiodes and electrode arrays. Lab on a Chip. 2013;13(5):785-97.

Arca F, Tedde SF, Sramek M, Rauh J, Lugli P, Hayden O.: Interface trap states in organic photodiodes. Scientific reports. 2013;3.

Arca F, Sramek M, Tedde SF, Lugli P, Hayden O.: Near-infrared organic photodiodes. IEEE Journal of Quantum Electronics. 2013;49(12):1016-25.

Arca F, Kohlstädt E, Tedde SF, Lugli P, Hayden O.: Large active area organic photodiodes for short-pulse X-ray detection. IEEE Transactions on Electron Devices. 2013.

Eminaga Y, Brischwein M, Becker S, Wiest J, Clauss J, Wolf B.: Self calibration of a planar dissolved oxygen sensor. Sensors & Actuators B. 2013, 177:785-791

Grundl D, Zhang X, Messaoud S, Pfister C, Demmel F, Mommer M S, Wolf B, Brischwein M.: Reaction-diffusion modelling for microphysiometry on cellular specimens. Medical and Biological Engineering and Computing. 2013, 51:387-395

Ziemiecka K, Struzycka I, Przemyslaw L, Perek J, Just M, Tyc M, Huzior J, Brischwein M.: Scientific description of an in vitro model of secondary caries test new bio-impedance detection method based on microbial marker. Polish Journal of Environmental Studies. 2013, 22:67-73

Iranmanesh I., Barnkob R., Bruus H., and Wiklund M.: Tunable-angle wedge transducer for improved acoustophoretic control in a microfluidic chip, J Micromech Microeng, 2013, 23, 105002

Muller P.B., Rossi M., Marín Á. G., Barnkob R., Augustsson P., Laurell T., Kähler C. J., and Bruus H.: Ultrasound-induced acoustophoretic motion of microparticles in three dimensions, Phys Rev E, 2013, 88, 023006

2012

Liu Y, Štefanić G, Rathouský J, Hayden O, Bein T, Fattakhova-Rohlfing D.: Assembly of mesoporous indium tin oxide electrodes from nano-hydroxide building blocks. Chemical Science. 2012;3(7):2367-74.

Hayden O, Latif U, Dickert FL.: A mass-sensitive approach for the detection of anaesthetic xenon. Australian Journal of Chemistry. 2012;64(12):1628-32.

Haigh PA, Ghassemlooy Z, Le Minh H, Rajbhandari S, Arca F, Tedde SF, et al.: Exploiting equalization techniques for improving data rates in organic optoelectronic devices for visible light communications. Journal of Lightwave Technology. 2012;30(19):3081-8.

Kleinhans R, Brischwein M, Wang P, Becker B, Demmel F, Schwarzenberger T, Zottmann M, Niendorf A, Wolf B.: Sensor-Based Cell and Tissue Screening for Personalized Cancer Chemotherapy. Medical and Biological Engineering and Computing. 2012, 50:117–126

Brischwein M, Scarpa G, Grothe H, Wolf B, Thalhammer S.: Toward printable lab-on-a-chip technologies for cell analytics. In: Biological and Medical Sensor Technologies, Kryzysztof Iniewski (ed.), 125-148, CRC press 2012, Print ISBN: 978-1-4398-8267-2, eBook ISBN: 978-1-4665-5257-9

Barnkob R., Augustsson P., Laurell T., and Bruus H.: Acoustic radiation- and streaming-induced microparticle velocities determined by micro-PIV in an ultrasound symmetry plane, Phys Rev E, 2012, 86, 056307

Muller P. B., Barnkob R., Jensen M. J. H., and Bruus H.: A numerical study of microparticle acoustophoresis driven by acoustic radiation forces and streaming-induced drag forces, Lab Chip, 2012, 12, 4617-4627

Adams* J. D., Ebbesen* C. L., Barnkob R., Yang A. H. J., Soh H. T., and Bruus H.: High-throughput, temperature-controlled microchannel acoustophoresis device made with rapid prototyping, J Micromech Microeng, 2012, 22, 075017, *Shared first authorship.

Barnkob R., Iranmanesh I., Wiklund M., and Bruus H.: Measuring acoustic energy density in microchannel acoustophoresis using a simple and rapid light-intensity method, Lab Chip, 2012, 12, 2337-2344

2011

Pichler S, Rauch T, Seyrkammer R, Böberl M, Tedde SF, Fürst J, et al.: Temperature dependent photoresponse from colloidal PbS quantum dot sensitized inorganic/organic hybrid photodiodes. Applied Physics Letters. 2011;98(5):21.

Nemec H, Mics Z, Kempa M, Kuzel P, Hayden O, Liu Y, et al.: Tuning the conduction mechanism in niobium-doped titania nanoparticle networks. The Journal of Physical Chemistry C. 2011;115(14):6968-74.

Lilliu S, Böberl M, Sramek M, Tedde SF, Macdonald JE, Hayden O.: Inkjet-printed organic photodiodes. Thin Solid Films. 2011;520(1):610-5.

Itskos G, Othonos A, Rauch T, Tedde SF, Hayden O, Kovalenko MV, et al.: Optical Properties of Organic Semiconductor Blends with Near‐Infrared Quantum‐Dot Sensitizers for Light Harvesting Applications. Advanced Energy Materials. 2011;1(5):802-12.

Hayden O, Nielsch K.: Molecular-and Nano-tubes: Springer Science & Business Media; 2011.

Wolf P, Hartl F, Brischwein M, Wolf B.: Determination of dynamic doxorubicin-EC50 value in an automated high-content workstation for cellular assays. Toxicology in Vitro. 2011, 25:1889-1894

Schwarzenberger T, Wolf P, Brischwein M, Kleinhans R, Demmel F, Lechner A, Becker B, Wolf B.: Impedance sensor technology for cell-based assays in the framework of a high-content screening system. Physiological Measurement. 2011, 32:977-993

Augustsson* P., Barnkob* R., Wereley S. T., Bruus H., and Laurell T.: Automated and temperature-controlled micro-PIV measurements enabling long-term-stable microchannel acoustophoresis characterization, Lab Chip, 2011, 11, 4152-4164, *Shared first authorship.

2010

Liu Y, Szeifert JM, Feckl JM, Mandlmeier B, Rathousky J, Hayden O, et al.: Niobium-doped titania nanoparticles: synthesis and assembly into mesoporous films and electrical conductivity. ACS nano. 2010;4(9):5373-81.

Barnkob R., Augustsson P., Laurell T., and Bruus H.: Measuring the local pressure amplitude in microchannel acoustophoresis, Lab Chip, 2010, 10, 563-570

2009

Tedde SF, Kern J, Sterzl T, Furst J, Lugli P, Hayden O.: Fully spray coated organic photodiodes. Nano letters. 2009;9(3):980-3.

Rauch T, Tedde SF, Hayden O.: NEAR-INFRARED IMAGING: Hybrid photodiodes promise cost-effective short-wave IR imaging. Laser Focus World. 2009;45.

Rauch T, Böberl M, Tedde SF, Fürst J, Kovalenko MV, Hesser G, et al.: Near-infrared imaging with quantum-dot-sensitized organic photodiodes. nature photonics. 2009;3(6):332-6.

Jenik M, Schirhagl R, Schirk C, Hayden O, Lieberzeit PA, Blaas D, et al.: Sensing picornaviruses using molecular imprinting techniques on a quartz crystal microbalance. Anal Chem. 2009;81(13):5320-6. doi: 10.1021/ac8019569.

Hoth CN, Steim R, Schilinsky P, Choulis SA, Tedde SF, Hayden O, et al.: Topographical and morphological aspects of spray coated organic photovoltaics. Organic Electronics. 2009;10(4):587-93.

Ugele M., Sasse F., Knapp S., Fedorov O., Zubriene A., Matulis D., Maier M.E.: Propionate analogues of zearalenone bind to Hsp90. Chembiochem. 2009 Sep 4;10(13):2203-12. doi: 10.1002/cbic.200900109.

Amaral CF, Brischwein M, Wolf B.: Multiparameter techniques for non-invasive measurement of blood glucose. Sensors and Actuators B. 2009, 140:12-16

2008

Hayden O, Agarwal R, Lu W.: Semiconductor nanowire devices. Nano Today. 2008;3(5):12-22.

2007

Hayden O, Zheng G, Agarwal P, Lieber CM.: Visualization of carrier depletion in semiconducting nanowires. small. 2007;3(12):2048-52.

Hayden O, Björk MT, Schmid H, Riel H, Drechsler U, Karg SF, et al.: Fully Depleted Nanowire Field‐Effect Transistor in Inversion Mode. Small. 2007;3(2):230-4.

Björk MT, Hayden O, Schmid H, Riel H, Riess W.: Vertical surround-gated silicon nanowire impact ionization field-effect transistors. Applied Physics Letters. 2007;90(14):142110.

Lob V, Geisler T, Brischwein M, Uhl R, Wolf B: Automated live cell screening system based on a 24-wellmicroplate with integrated micro fluidics. Medical and Biological Engineering and Computing. 2007, 45:1023-1028

2006

Hayden O, Podlipna D, Chen X, Krassnig S, Leidl A, Dickert FL.: Nanolithography and subnanomolecular interactions for biomimetic sensors. Materials Science and Engineering: C. 2006;26(5):924-8.

Hayden O, Mann K-J, Krassnig S, Dickert FL.: Biomimetic ABO blood-group typing. Angew Chem Int Ed Engl. 2006;45(16):2626-9. doi: 10.1002/anie.200502857.

Hayden O, Mann KJ, Krassnig S, Dickert FL.: Biomimetische AB0‐Blutgruppenbestimmung. Angewandte Chemie. 2006;118(16):2688-91.

Hayden O, Lieberzeit PA, Blaas D, Dickert FL.: Artificial antibodies for bioanalyte detection—Sensing viruses and proteins. Advanced Functional Materials. 2006;16(10):1269-78.

Hayden O, Haderspöck C, Krassnig S, Chen X, Dickert FL.: Surface imprinting strategies for the detection of trypsin. Analyst. 2006;131(9):1044-50. doi: 10.1039/b608354b.

Hayden O, Agarwal R, Lieber CM.: Nanoscale avalanche photodiodes for highly sensitive and spatially resolved photon detection. Nature materials. 2006;5(5):352.

Dickert FL, Lieberzeit PA, Hayden O.: Molecularly imprinted polymers for mass sensitive sensors: from cells to viruses and enzymes. Molecular imprinting of polymers. 2006:50-63.

Sprague L, Beregov V, Sternbach G, Brischwein M, Otto AM, Adam M, Wolf B, Molls M.: Multiparametric sensor chip-based technology for monitoring metabolic activity: A proof-of-Principle study with live tissue. Journal of Clinical Laboratory Analyses. 2006, 52:375-384

Brischwein M, Herrmann S, Vonau W, Berthold F, Grothe H, Motrescu E, Wolf B.: Electric cell-substrate impedance sensing with screen printed electrode structures. Lab on a Chip. 2006, 6:819-822

2005

Lieberzeit PA, Glanznig G, Jenik M, Gazda-Miarecka S, Dickert FL, Leidl A.: Softlithography in chemical sensing–analytes from molecules to cells. Sensors. 2005;5(12):509-18.

Hayden O, Payne CK.: Nanophotonic light sources for fluorescence spectroscopy and cellular imaging. Angewandte Chemie International Edition. 2005;44(9):1395-8.

Hayden O, Greytak AB, Bell DC.: Core–shell nanowire light‐emitting diodes. Advanced Materials. 2005;17(6):701-4.

Motrescu ER, Otto AM, Brischwein M, Zahler S, Wolf B.: Dynamic analysis of metabolic effects of chloroacetaldehyde and cytochalasin B on tumor cells using bioelectronic sensor chips. Journal of Cancer Research and Clinical Oncology 2005, 131:683-691

2004

Patolsky F, Zheng G, Hayden O, Lakadamyali M, Zhuang X, Lieber CM.: Electrical detection of single viruses. Proceedings of the National Academy of Sciences of the United States of America. 2004;101(39):14017-22.

Dickert FL, Lieberzeit PA, Hayden O, Schirk C, Halikias K.: Molocular imprinting-a universal strategy for the development of chemosensors. VDI BERICHTE. 2004;1829:611-6.

Dickert FL, Lieberzeit PA, Gazda-Miarecka S, Mann K-J, Hayden O, Palfinger C.: Synthetic receptors for chemical sensors--subnano- and micrometre patterning by imprinting techniques. Biosens Bioelectron. 2004;20(6):1040-4. doi: 10.1016/j.bios.2004.07.011.

Dickert FL, Hayden O, Bindeus R, Mann K-J, Blaas D, Waigmann E.: Bioimprinted QCM sensors for virus detection-screening of plant sap. Anal Bioanal Chem. 2004;378(8):1929-34. doi: 10.1007/s00216-004-2521-5.

Henning T, Kraus M, Brischwein M, Otto AM, Wolf B.: Relevance of Tumor Microenvironment for progression, therapy and drug development. Anti-Cancer Drugs. 2004, 15:7-14

Otto AM, Brischwein M, Motrescu E, Wolf B.: Analysis of drug action on tumor cell metabolism using electronic sensor chips. Archiv der Pharmazie. 2004, 337:682-686

2003

Hayden O, Bindeus R, Haderspöck C, Mann K-J, Wirl B, Dickert FL.: Mass-sensitive detection of cells, viruses and enzymes with artificial receptors. Sensors and Actuators B: Chemical. 2003;91(1):316-9.

Hayden O, Bindeus R, Dickert FL.: Combining atomic force microscope and quartz crystal microbalance studies for cell detection. Measurement Science and Technology. 2003;14(11):1876.

Dickert FL, Lieberzeit PA, Hayden O, Gazda-Miarecka S, Halikias K, Mann K-J, et al.: Chemical sensors–from molecules, complex mixtures to cells–supramolecular imprinting strategies. Sensors. 2003;3(9):381-92.

Dickert FL, Lieberzeit PA, Hayden O, Bindeus R, Mann K-J, Haderspöck C.: Selfassembling around Templates–Creating Nano Dots and Pits for Chemical Sensing–. MRS Online Proceedings Library Archive. 2003;776.

Dickert FL, Lieberzeit PA, Hayden O.: Chemische Sensoren durch Molekulares Prägen. Nachrichten aus der Chemie. 2003;51(11):1139-43.

Dickert FL, Lieberzeit PA, Hayden O.: Sensor strategies for microorganism detection--from physical principles to imprinting procedures. Anal Bioanal Chem. 2003;377(3):540-9. doi: 10.1007/s00216-003-2060-5.

Dickert FL, Hayden O, Lieberzeit PA, Haderspöck C, Bindeus R, Palfinger C, et al.: Nano-and micro-structuring of sensor materials—from molecule to cell detection. Synthetic Metals. 2003;138(1):65-9.

Dickert F, Hayden O, Lieberzeit P, Palfinger C, Pickert D, Wolff U, et al.: Borderline applications of QCM-devices: synthetic antibodies for analytes in both nm-and μm-dimensions. Sensors and Actuators B: Chemical. 2003;95(1):20-4.

Brischwein M, Motrescu ER, Otto AM, Cabala E, Grothe H, Wolf B.: Functional Cellular Assays with Multiparametric Silicon Sensor Chips. Lab on a Chip. 2003, 3:234-240

2002

Dickert FL, Hayden O.: Bioimprinting of polymers and sol-gel phases. Selective detection of yeasts with imprinted polymers. Anal Chem. 2002;74(6):1302-6.

2001

Hayden O, Haderspöck C, Dickert FL.: Microorganism Detection With Selective Bioimprinted Polymers and Sol-Gels. INTERNATIONAL JOURNAL OF BIOCHROMATOGRAPHY. 2001;6:303-11.

Hayden O, Dickert FL.: Selective microorganism detection with cell surface imprinted polymers. Advanced Materials. 2001;13(19):1480-3.

Dickert FL, Hayden O, Halikias KP.: Synthetic receptors as sensor coatings for molecules and living cells. Analyst. 2001;126(6):766-71.

Dickert FL, Hayden O.: Non-covalent molecularly imprinted sensors for vapours, polyaromatic hydrocarbons and complex mixtures. Techniques and Instrumentation in Analytical Chemistry. 2001;23:503-25.

Dickert FL, Halikias K, Hayden O, Piu L, Sikorski R.: Sensors based on fingerprints of neutral and ionic analytes in polymeric materials. Sensors and Actuators B: Chemical. 2001;76(1):295-8.

2000

Dickert FL, Hayden O, Halikias K, Lieberzeit PA, Rohrer A, Bulst W-E, et al.: Molekular geprägte Chemosensoren fur die Qualitätskontrolle. VDI BERICHTE. 2000;1530:1051-6.

Dickert FL, Hayden O.: Molecular fingerprints using imprinting techniques. Advanced Materials. 2000;12(4):311-4.

1999

Dickert FL, Hayden O, Zenkel M.: Detection of volatile compounds with mass-sensitive sensor arrays in the presence of variable ambient humidity. Anal Chem. 1999;71(7):1338-41. doi: 10.1021/ac981014e.

Dickert FL, Hayden O.: Imprinting with sensor development–On the way to synthetic antibodies. Fresenius' journal of analytical chemistry. 1999;364(6):506-11.

Dickert FL, Hayden O.: Molecular imprinting in chemical sensing. TrAC Trends in Analytical Chemistry. 1999;18(3):192-9.

Dickert FL, Greibl W, Hayden O, Lieberzeit PA, Sikorski R, Tortschanoff M, et al.: Development of materials for chemical sensors-From molecular cavities to imprinting techniques. Advances in science and technology. 1999:175-82.

1998

Dickert FL, Greibl W, Hayden O, Lieberzeit PA, Tortschanoff M, Bulst W-E, et al.: Chemosensoren mit molekulargeprägten Erkennungsschichten-Technologie der analytspezifischen Sensoradaption. ITG FACHBERICHT. 1998:133-8.

 

Conference proceedings 

Haigh PA, Ghassemlooy Z, Bausi F, Papakonstantinou I, Le Minh H, Tedde SF, et al., editors.: Organic visible light communications: Recent progress. Transparent Optical Networks (ICTON), 2014 16th International Conference on; 2014: IEEE.

Haigh PA, Ghassemlooy Z, Papakonstantinou I, Tedde F, Tedde SF, Hayden O, et al., editors.: A MIMO-ANN system for increasing data rates in organic visible light communications systems. Communications (ICC), 2013 IEEE International Conference on; 2013: IEEE.

Dickert FL, Hayden O, Chen X, Krassnig S, Kauling J, editors. Acoustic transducers and soft-lithography-detection of biological analytes. Industrial Electronics, 2005 ISIE 2005 Proceedings of the IEEE International Symposium on; 2005: IEEE.

Greibl W, Hayden O, Achatz P, Fischerauer G, Scholl G, Dickert FL, editors.: Surface phenomena with organic coatings for chemical sensing. Proceedings of the SPIE; 2002.

Dickert FL, Hayden O, Lieberzeit PA, Palfinger C.: Sensor Materials-Detecting Molecules, Mixtures and Microorganisms. MRS Online Proceedings Library Archive. 2002;723.

Dickert FL, Greibl W, Haderspock C, Hayden O, Rohrer A, Scholl G, et al., editors.: QCM and SAW transducers allow analyte detection from nanometer-to micrometer-dimensions using imprinting techniques. Frequency Control Symposium and PDA Exhibition, 2001 Proceedings of the 2001 IEEE International; 2001: IEEE.

Dickert FL, Bulst W-E, Hayden O, Ping L, Achatz P, Sikorski R, et al., editors.: Moulding of polymers for chemical sensors-: Strategies of analyte detection and mixture characterization. Proceedings of SPIE, the International Society for Optical Engineering; 2001: Society of Photo-Optical Instrumentation Engineers.

Dickert FL, Greibl W, Hayden O, Sikorski R, Tortschanoff M, Weber K, et al.: Sensors for Gas and Liquid Phases with Molecularly Imprinted and Selforganized Layers. Proceedings Sensor 99. 1999;1:183-8.

Dickert FL, Achatz P, Bulst W-E, Greibl W, Hayden O, Ping L, et al., editors.: Self-organized polymers as sensitive coatings. Photonics East'99; 1999: International Society for Optics and Photonics.